6/30/2018

Giga Tronics 1026 Manual Transmission

Gigatronics 2520b

The Analytical Instrumentation Handbook serves as a guide for workers in. Analog Signal Transmission. Manual Data Interpretation. 1026: Synthesized Signal. The Analytical Instrumentation Handbook serves as a guide for workers in. Analog Signal Transmission. Manual Data Interpretation. 1026: Synthesized Signal.

• September 1998 Operation & Maintenance Manual Model GT 9000 Microwave Synthesizer... Certified Product ISO 9001. • WARRANTY Giga-tronics products are warranted against defective materials and workmanship for one year from date of shipment. Giga-tronics will at its option repair or replace products that are proven defective during the warranty period. This warranty DOES NOT cover damage resulting from improper use, nor workmanship other than Giga-tronics service. • Table of Contents About This Manual.Conventions.

• GT 9000 Syntax Virtual Keystrokes. • Preface 3.3.20 Pushbutton — PC Assembly A105.3-33 3.3.21 Data Entry —. • Series GT 9000 Microwave Synthesizers 5.3.7 Level Control Circuit. • GT 9000 PCB Assy Set,, DWG# 120DA00750. • Series GT 9000 Microwave Synthesizers Power Supply Circuit Schematic (A11), DWG# 120BS04650... 7-49 100 MHz Ref PLL PC Assy (A14), DWG# 120BA06951. • Preface A • Options __________________________________________________________ A.1 Introduction...

A.2 Accessory A001: Cable Kit (SMA), P/N 29847. • Series GT 9000 Microwave Synthesizers List of Figures ________________________________________________________ Figure 1-1 Power Line Connection. • 2-20 Table 2-5 GT 9000 Virtual Keystrokes.2-24 Table 2-6 Character Representations. • Series GT 9000 Microwave Synthesizers Manual No. 120AM00250, Rev C, September 1998. • About This Manual This Operation and Maintenance Manual covers all aspects of the Giga-tronics Model GT 9000 Synthesized Microwave Signal Generator. The information required to operate, calibrate and maintain the instrument is provided.

Chapter 1 — Introduction & Performance Specifications — This chapter contains a brief introduction to the instrument as well as the instrument’s performance parameters. Ucinet Cracker. • Series GT 9000 Microwave Synthesizers Manual No. 120AM00250, Rev C, September 1998. • Conventions The following conventions are used in this product manual. Additional conventions not included here will be defined at the time of usage.

Warning WARNING The WARNING statement is enclosed in double lines and centered in the page. This calls attention to a situation, or an operating or maintenance procedure, or practice, which if not strictly corrected or observed, could result in injury or death of personnel. • Series GT 9000 Microwave Synthesizers SYMBOLS Block diagram symbols frequently used in the manual are illustrated below.

Course Fine STEP ATTEN Pulse YIG-Tuned Mixer Switch Step PIN-Diode Modulator Oscillator Attenuator Leveler PASS RF Level Voltage- Digital to Fixed Filter Detector. • Record of Manual Changes This table is provided for your convenience to maintain a permanent record of manual change data. Corrected replacement pages will be issued as Technical Publication Change Instructions, and will be inserted at the front of the binder. Remove the corresponding old pages, insert the new pages, and record the changes here.

• Series GT 9000 Microwave Synthesizers Manual No. 120AM00250, Rev C, September 1998. • Special Configurations When the accompanying product has been configured for user-specific application(s), supplemental pages will be inserted at the front of the manual binder. Remove this page and replace it with the furnished Special Configuration supplemental page(s). Xvii Manual No.